Hydro Testing Corrosion Inhibitor RXSOL 4000 is a multicomponent, multifunctional formulation which prevents corrosion, microbiological growth in single product treatment programme. Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications.
REMIDOL 4000, Hibitol 2000, Indion 175, Visco 3900, Nevamine, Hydrotesting Corrosion Inhibitor, Visco Nalco 3900, Tretolite WF-166, Hydro Testing Corrosion Inhibitor 220 Kg PACK
PERFORMANCE:
CORROSION: Effectively prevents corrosion due to Carbon Dioxide, inorganic salts, dissolved oxygen & Hydrogen sulphide contamination from sour fluid or bacterial action. The inhibitor acts as a cathodic polarizer
MICROBIOLOGICAL GROWTH: Effectively prevents the metabolic function necessary for reproduction of the bacteria cell. Successfully prevents anaerobic/aerobic and sulphate reducing bacteria.


Hydro Testing Corrosion Inhibitor ( RXSOL 4000 ) can be fed directly or through chemical doses pump. Doses may vary with the quality of water to be treated and the residence time of the water in the system.
Actual consumption is determined under operating conditions.
Benefit / Advantage :
Hydro Testing Corrosion Inhibitor RXSOL 4000 is a liquid multifunctional chemical designed to completely treat hydrostatic test fluid, saltwater packer fluid, saltwater drilling fluid, during Hydro-testing and oil field water injection programme.
Hydro Testing Corrosion Inhibitor RXSOL 4000 contains an effective filming corrosion inhibitor, oxygen scavenger and biocide, altogether in a single formulation convenient to dose with single chemical injection pump or skid.
Hydro Testing Corrosion Inhibitor RXSOL 4000 is economical to use as handling is limited to one chemical.
Pipeline corrosion inhibitor manufacturer and supplier. Hydro Testing Corrosion Inhibitor RXSOL 4000 provide complete protection against rust and scale.
Chemical for conditioning of hydro test water i.e. blend of corrosion inhibitor, one Oxygen scavenger, one scale inhibitor & one biocide
The major factor which contributes to the corrosion in hydro-static test water is the dissolved oxygen and dissolved solids do not have much impact on the corrosion rate except the chloride content. The presumptions like not using the corrosion inhibitor if the water is not with high mineral content could beM disastrous as in fact any corrosion process, even a very mild one, will be accompanied by the set up of galvanic cells and formation of corrosion products deposits. Such environment makes the conditions ideal for the corrosion process to continue at accelerated rate once the process fluid will be run through the line.
Hydro Testing Corrosion Inhibitor RXSOL 4000 is Hydro-testing corrosion protection for Pipeline, Tank. RXSOL 4000 Chemical for conditioning of hydro test water i.e. blend of corrosion inhibitor, one Oxygen scavenger, one scale inhibitor & one biocide manufacturer exporter and supplier Mumbai, Surat, Gandhidham, Chennai, Ennore, Visakhapatnam, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Dubai UAE Middle East, Muscat Oman Sohar
Effect of Micro – Organisms:
All water used for Hydro-testing generally contains iron bacteria and sulphate reducing bacteria. The iron bacteria attack to the pipe wall mostly at 6 o’clock location and produces tubercle of iron oxide by metabolic action. Below the tubercles, sulphate reducing bacteria grows and generates H2S from sulphate of water. The H2S goes on reacting with iron forming Fe2S. This is combined with auto catalytic formation of HCI under tubercle and lead to deep pitting and perforation of the pipe wall. The mechanism is more pronounced under stagnant condition and is relevant of Hydrostatic testing.
#HydroTestingINHIBITOR_UAE
Corrosion Inhibitor Injection