VapourTreatment (For controlling of Scale & Foam)
This is a highly active antifoulant, water scale inhibitor, dispersant and anti-precipitant compound for use in industrial and marine water systems, such as cooking systems, heat exchangers, air conditioning equipment, etc.
REMIDOL 1500, Green Eva, Care Treat 1 Evaporator, Evatreat Evaporator Treatment., ET 109 NorChem
Procedure Of Use and Dose Rates: POLYELECTROLYTE polymer of RXSOL-51-6001-025 reacts with the potential scale forming salts in the water to prevent them from adhering to heat transfer surfaces. These solids are held in suspension and easily removed from the evap -orator line .Finally RXSOL-51-6001-025 also have defoaming properties by which will stop foaming in EVAPORATOR.And by that way Distilled water quality is maintained in side the EVAPORATOR.
Used in both high and low pressure evaporators




Dosage :
Daily Out Put Evaporator | Daily RXSOL VT 6001 Requirement |
10 - 20 MT | 100-200 ML |
30 – 40 MT | 300-400 ML |
50 – 60 MT | 500-600 |
Setting the Flow Rate: The treatment is added to the dosage tank and mixed with water. Example: With the 0.5 litres of Vaptreat add sufficient water to make up 50 litres of liquid.The standard flow meter is Adjustable-Rate=0-l00ml/minute.Flow rate calculation: Flowrate = 50 Litres/24 x 60= 35 ml/min setting i.eThis will last 24 hours.
Note: We can remover existing mineral scale deposits by using A 5-10% solution of RXSOL-51-6001-020
Improves the quality of distilled water
Evaporator Treatment Chemical manufacturer and supplier in Mumbai, Fujairah, Muscat, Nairobi Kenya, Kolkata, Chennai, Vizag, Gandhidham, Dubai, sharjah, Ajman, Abudhabi, Barka Sohar Oman, Canada Africa Jinja Uganda
Why Evaporator Treatment Chemicals must use?
PREVENTION OF SCALING IN SEA WATER EVAPORATORS.
RXSOL Vapor Treatment Prevents scale formation at temperatures up to 160°C Also Reduces foaming and maintains optimum plant performance.
During distilled water production in seawater evaporators, SCALE CONTROL is very important to increase efficiency of distillation as the seawater contains large quantities of salt which is resulting SCALE FORMATION in heat transfer surfaces. Scale deposits Not only lower plant efficiency by resisting the transfer of heat, But also damaging instruments. Routine use of RXSOL Vapor Treatment prevents Scale formation in the Evaporator SYSTEM.
Whats the Dose Ratio of RXSOL VAPOR TREATMENT Chemicals?
Dilute the RXSOL VAPOR TREATMENT chemicals with water and continuously inject via evaporator inlet or the salt water supply lineand dose into the evaporator system. 30 ml Dose per ton of Seawater is recommended for the prevention of scaling in seawater evaporators. Dose can vary depends on the capacity and the operating conditions of the evaporator.
Note: for the gradual removal of existing scale deposits, at least twice the normal dose must be used. Remove deposits of more than 2mm, with Descalex Liqui