Evaporator Coil Cleaner

$
0
0

Evaporator Coil Cleaner is a special blend of effective ingredients designed to penetrate and remove built-up grease, dirt and oxidation from finned coils, cleaning in one step. Evaporator Coil Cleaner DOES NOT CONTAIN ACID.
Buildup of greasy dirt on air conditioning or refrigeration cooling coils makes the units work much harder. Impeded air flow and poor heat transfer can put a sever strain on both the equipment and the pocket book. Cleaning removes dirt and greasy film from evaporator coils and enables the equipment to operate more efficiently.

Alias: 

Greenleaf Evaporator Coil Cleaner

Active Matter: 
54 - 58
Application: 

What is EVAPORATOR PLANT ?

For production of fresh water Large ships usually carry evaporating plants.  
Steam ships must be able to produce high-quality distillate in order to maintain boiler-water levels.

Diesel-engined ships often utilise waste heat as an energy source for producing fresh water. In this system, the engine-cooling water is passed through a heat exchanger, where it is cooled by concentrated seawater (brine). Because the cooling water (which is chemically treated fresh water) is at a temperature of 70–80 °C (158–176 °F), it would not be possible to flash off any water vapour unless the pressure in the heat exchanger vessel was dropped. To alleviate this problem, a brine-air ejector venturi pump is used to create a vacuum inside the vessel. Partial evaporation is achieved, and the vapour passes through a demister before reaching the condenser section. Seawater is pumped through the condenser section to cool the vapour sufficiently to precipitate it. The distillate gathers in a tray, from where it is pumped to the storage tanks. A salinometer monitors salt content and diverts the flow of distillate from the storage tanks if the salt content exceeds the alarm limit. Sterilisation is carried out after the evaporator.

Evaporators are usually of the shell-and-tube type (known as an Atlas Plant) or of the plate type (such as the type designed by Alfa Laval). Temperature, production and vacuum are controlled by regulating the system valves. Seawater temperature can interfere with production, as can fluctuations in engine load. For this reason, the evaporator is adjusted as seawater temperature changes and shut down altogether when the ship is manoeuvring. An alternative in some vessels, such as naval ships and passenger ships, is the use of the reverse osmosis principle for fresh-water production, instead of using evaporators.

MECHANISM of EVAPORATOR :::---
Lots of heat is absorbed in the process this is called the latent heat of vaporization and makes for very efficient heat transfer because the freon is vaporizing in this coil, it is called the evaporator coil Freon makes an excellent heat transfer material at atmospheric pressure, it is a colourless gas when it boils. absorbs a lot of heat when it condenses from a gas to a liquid, it gives off a lot of heat  (this is helpful when discharging heat to the outside through the condensing coil)

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

¨ Economical - mix one part Evaporator Coil Cleaner to four parts water.
¨ Safer than acid cleaners.
¨ Cleans coils in one step - no rinsing needed.
¨ High foaming for faster penetration

OTHER GRADE of COIL CLEANER :::

Condenser Coil Cleaner   RXSOL-50-5015-025 ( condenser coil cleaner and brightener )

Coil Brite Rx Yellow          RXSOL-16-1680-005  ( For Oxide and dirt removal )

Air Cooler Cleaner            RXSOL-16-0009-025 ( For cleaning of greasy materials )

Note: 

Use Instructions:
1. Protect eyes and skin with appropriate safety items.
2. May be used with unit on or off.
3. Use low pressure spraying tank.
4. Mix one part Evaporator Coil Cleaner to four parts water.
5. Spray Evaporator Coil Cleaner solution into coils and allow approximately a ten minute contact time for best results. Condensate will rinse coils. Rinse filters with clean water.

RXSOL brand is very popular as a Evaporator Coil Cleaner manufacturer. And our group division have Evaporator Coil Cleaner supplier network for manglore, Navi Mumbai, Goa, Mumbai, Kakinada, Gangavaram, Vizag, Visakhapatnam, Ennore, Chennai, kandla, mundra, sikka, Surat, Fujairah, Sharjah, Dubai, Abudhabi, Middle East, Gulf. we are RXSOL Evaporator Coil Cleaner exporter for Saudi Arabia, Iraq and Kuwait.

Short Description: 
Ingredients designed to penetrate and remove built-up grease, dirt and oxidation from finned coils, cleaning in one step. Cleaning and removal of dirt and greasy film from evaporator coils and enables the equipment to operate more efficiently.

It is a specially engineered condenser coil cleaner and brightener have safe bioderadable non acidic formula. this product is recommended for use in hotels, commercial complexes, hospitals, shipyards, Heavy Industries and it can be used indoors making it highly suitable for cleaning refrigeration units in shopping malls, food shops, supermarkets, butchers and wet fish shops.  and any air-conditioning workshops or establishments that services air conditioning systems. 

RXSOL-51-6004-025 Clean Evaporator coil is the first step in ensuring maximum compressor efficiency.  Coil Cleaner has a foam that cleans heating and refrigeration coils, fins and fan blades. As the foam breaks down, it carries away dirt, dust, grease, oil and other residue

RXSOL-51-6004-025  coil cleaner will not corode coils and is safe to use on surrounding metals and other HVAC equipment components.

Cooling coils trap dust, soil, grime and other troublesome deposits that reduce the heat transfer efficiency of HVAC units. This build-up interferes with proper system operations. RXSOL-51-6004-025 Coil Cleaner effectively removes accumulated build-up, restores operating efficiency and prepares the unit for the control of harmful organisms with Greenleaf Aquacide QLF Microbiocide.

RXSOL-51-6004-025 Cleaner effectively cleans and deodorizes evaporator coils, heating coils, condenser coils, window units, air filters, blowers, and other dirty HVAC components. RXSOL-51-6004-025 Coil Cleaner is safe for all metal, including aluminium.

RXSOL evaporator coil cleaner is the perfect first step in improving compressor effeciency.

Diesel-engined ships often utilise waste heat as an energy source for producing fresh water. In this system, the engine-cooling water is passed through a heat exchanger, where it is cooled by concentrated seawater (brine). Because the cooling water (which is chemically treated fresh water) is at a temperature of 70–80 °C (158–176 °F), it would not be possible to flash off any water vapour unless the pressure in the heat exchanger vessel was dropped. To alleviate this problem, a brine-air ejector venturi pump is used to create a vacuum inside the vessel. Partial evaporation is achieved, and the vapour passes through a demister before reaching the condenser section. Seawater is pumped through the condenser section to cool the vapour sufficiently to precipitate it. The distillate gathers in a tray, from where it is pumped to the storage tanks. A salinometer monitors salt content and diverts the flow of distillate from the storage tanks if the salt content exceeds the alarm limit. Sterilisation is carried out after the evaporator.

Evaporators are usually of the shell-and-tube type (known as an Atlas Plant) or of the plate type (such as the type designed by Alfa Laval). Temperature, production and vacuum are controlled by regulating the system valves. Seawater temperature can interfere with production, as can fluctuations in engine load. For this reason, the evaporator is adjusted as seawater temperature changes and shut down altogether when the ship is manoeuvring. An alternative in some vessels, such as naval ships and passenger ships, is the use of the reverse osmosis principle for fresh-water production, instead of using evaporators.

MECHANISM of EVAPORATOR :::---
Lots of heat is absorbed in the process this is called the latent heat of vaporization and makes for very efficient heat transfer because the freon is vaporizing in this coil, it is called the evaporator coil Freon makes an excellent heat transfer material at atmospheric pressure, it is a colourless gas when it boils. absorbs a lot of heat when it condenses from a gas to a liquid, it gives off a lot of heat  (this is helpful when discharging heat to the outside through the condensing coil)

Evaporator Coil Cleaner DOES NOT CONTAIN ACID.


Condensnol Amine 20 Ltrs

$
0
0

RXSOL-50-5005-20  Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2 throughout a condensate system. Protects boiler surfaces by forming an iron tannate film.

Alias: 

GREEN CC, Nalfleet 9-150 / SLCC-A, Care Treat-4, Condensate Control, MARICHEM C.C.I.TM,Maxtreat 3330, DM-530

Active Matter: 
88 - 93 %
Application: 

RXSOL-50-5005-20 is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition
 

FIELDS OF APPLICATIONS :-
RXSOL-50-5005-20 is an effective neutralizing type corrosion inhibitor & oxygen scavanger  for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe2O3 (rust) to organic iron compound protect further IRON rust reaction .

OPERATING PROCESS :-
RXSOL-CC72 neutralizes the acid components of feed water.The proportion of RXSOL-50-5005-20 depends upon the Carbon dioxide content of the condensate. Basically RXSOL-50-5005-20 neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition.  It also protects copper based metals.

Packing Size: 
20.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

RXSOL-50-5005-20 condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10 M3, the dosage is approximately 0.65 ltr / day .

The necessary amount of RXSOL-50-5005-20 is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.

Note: 
  • Easy to use liquid treatment.
  • Neutralizes the acids occurring in the condensate system.
  • Less maintenance required. Lower operating costs and increased reliability.
  • Volatilizes and carries over with the steam and so is recycled. Dosage is economical and efficient.
  • Simple test to determine level of treatment.
  • Used for protection of condensate and feed water systems in boiler systems of all pressures.
Short Description: 
LIQUID CONDENSATE CORROSION CONTROL FOR BOILER SYSTEMS

We are also keeping ready stock of full range of marine chemicals, Some of valuable marine products are as follows :::

AQUATUFF
CHLORINATED ISOCYANURATE TABLETS
CHLORINE Liquid
Oil Spill Dispersant
DESCALING LIQUID
DISCLEAN
ELECTROSOLV E
ENVIROCLEAN
PERMANGANATE TABLETS
ROCOR NB LIQUID
VAPTREAT

Condensate Control

Corroision Inhibitor for Oxygen Control 20 Ltr

$
0
0

Oxygen Control Corroision Inhibitor

Alias: 

GREEN OC, SPEC HIB 310ES

Active Matter: 
27-36%
Application: 

COMMON NAME : Oxygen control corroision inhibito for FEROUS & ALUMINUM

Packing Size: 
20.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

RXSOL-50-5007-020 The objective is to maintain a hydrazine residual between 0.05-0.2 ppm depending on operating pressure and boiler designe. Actual consumption is determined under operating conditions. A normal dosage is approximately 1 ltr. per day, depending of system layout.  The calculated LC50 is 172,891 ppm with a 95% confidence interval of 123,414 ppm and 237,006 ppm.

Powder Application:-

For average conditions the recommended dosage is 0.30 ounces (weight) per cubic foot (28 Liters) of enclosed space.( 300 g/cubic meter) Concentration can be increased to protect metals under more severe conditions. Powder is applied by air fogging or sprinkle and then the treated area is closed or sealed.

Liquid Application:-

For average conditions the recommended dosage as a solution is a 0.25% in water (based upon weight). This solution is recommended as a hydrostatic test fluid or as an additive to a final rinse in metalworking applications. Concentration can be increased to protect metals under more severe conditions. The treated area is then closed or sealed.
 

Hydrazine is a convenient reductant because the by-products are typically nitrogen gas and water. Thus, it is used as an ANTIOXIDANT, an oxygen scavenger, and a corrosion inhibitor in water boilers and heating systems. 

Hydrazine is mainly used as a foaming agent in preparing polymer foams 

Note: 

More about Water Boiler Treatment & Powder / liquid Inhibitors

scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boiler rupture

By using this corrosion inhibitor / oxygen control the build up of sediment deposits and damaging corrosion of water boilers is greatly reduced. Our research and experience recomend  to working water boilers at a rate of 0.5 to 1.0 percent of the weight of water in the system. This amounts to 4 up to 8 pounds of powder corrosion inhibitor in 100 gallons of water

 

TEST METHOD ::: http://rxmarine.com/hydrazine-test-kit

Short Description: 
It is a corrosion inhibitor is a catalyzed liquid catatonic, filming amine corrosion inhibitor and oxygen scavenger , This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental cond

read more

Vap Treat SOL 25 Ltr

$
0
0

VapourTreatment  (For controlling of Scale & Foam) ::: Neutral Liquid for prevention of scale in seawater Evaporators
This is a highly active antifoulant, water scale inhibitor, dispersant and anti-precipitant compound for use in industrial and marine water systems, such as cooking systems, heat exchangers, air conditioning equipment, etc.

Alias: 

Vaptreat L, Nalfleet Maxi-Vap Plus, Ameroyal, Vaptreat L, Liquivap HC 130, Ameroyal CF, Eazy Vapcare

Application: 

Procedure Of Use and Dose Rates: POLYELECTROLYTE  polymer  of RXSOL-51-6001-025 reacts with the potential scale forming salts in the water to prevent them from adhering to heat transfer surfaces. These solids are held in suspension and  easily removed  from  the evaporator  line. Finally RXSOL-51-6001-025 also have defoaming properties by which will stop foaming in EVAPORATOR. And by that way Distilled water quality is maintained in side the EVAPORATOR.

Used in both high and low pressure evaporators. 

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Dosage :

Daily Out Put Evaporator Daily  RXSOL VT 6001 Requirement
10  - 20 MT 100-200 ML
30 – 40 MT 300-400 ML
50 – 60 MT 500-600

Setting the Flow Rate: The treatment is added to the dosage tank and mixed with water. Example: With the 0.5 litres of Vaptreat add sufficient water to make up 50 litres of liquid.The standard flow meter is Adjustable-Rate=0-l00ml/minute.Flow rate calculation: Flowrate = 50 Litres/24 x 60= 35 ml/min setting  i.eThis will last 24 hours.

Note: We can remove  existing  mineral scale deposits  by using  A  5-10%  solution of  RXSOL-51-6001-025 Otherwise to save money and cleaning of HARD DEPOSITS which is formed due to not proper treratment of Evaporator, we have specialized Safe Scale Remover with Indicator ( Product code is RXSOL-22-2210-200 ).

Note: 

Improves the quality of distilled water. 

Short Description: 
Neutral Liquid for prevention of scale in seawater Evaporators
Information: 

Vaptreat - directly control scale deposition in evaporators water formation system. Since 1995 we are working with same product formulation and addition of composite polymer electrolytes not only helps to increase repulsion force in between scale formation molecule but also helps to keep evaporator maintenance free. We are one of popular supplier of vaptreat in Mumbai, Kandla, Mundra, Sikka, Manglore, Goa, Vizag, Chennai, Ennore, Kolkata, Haldia and all surrounding Indian as well as Middle East port. 

VAPT REAT Evaporator Treatment Chemicals supplier in Mumbai, Kandla - Deen Dayal Upadhyay Port, Gandhidham, Chennai - Ennore, Visakhapatnam - Gangavaram, Kolkata - Haldia, Paradip, Fujairah, Dubai, Sharjah, Ajman, AbuDhabi - Middle East - UAE.

Evaporator Treatment Chemicals

read more

Air Cooler Cleaner 25 Ltr

$
0
0

Alias: 

Mite ACC, Nalfleet® 79101 ACC, Care Clean ACC , Air Cooler Cleaner Merichem, Cleaner 622, EAZY ACC, SEA SHIELD ACC 79101, AC cleaner

Active Matter: 
94%
Application: 

During the operation, the fins & tubes of the main engine air cooler which become fouled with oil, grease, dust and carbonaceous deposit , which will affect cooler efficiency and damage the system.

Dirt attached on air-side fins of air coolers are a mix of carbonaceous particles such as soot and oil mist of unburned fuel components. 
Carbonaceous particles can be removed by Alkaline Cleaners Part No. RXSOL-16-1040-025 ( www.rxmarine.com/alkaline-air-cooler-cleaner ) and oil mist can be removed by oil based cleaners. However, it is very difficult to remove the mix of these substances. If you use an alkaline cleaner, oil will repel the water based alkaline cleaner; if you use oil based cleaner, carbonaceous particles will get in the way and stop oil from being removed.

This cleaners designed to remove both carbonaceous and oil simultaneously. An effective cleaning method is to immerse one side to remove the loose stains first, and then immerse the other side. This method can efficiently remove dirt and prevent swollen dirt peeled from fins from blocking the spaces between fins.

Dirt in tubes of seawater side

White scales attached on the seawater side of air coolers of many vessels. We found that in most cases, the main component of the scales is calcium carbonate and there is also a small amount of calcium sulfate. Therefore in most cases, if you dissolve the calcium carbonate the scales will be removed.

However, if the amount of scales is large enough to block the tube, the cylindrical scale will usually have calcium carbonate on the outside (the side that is in contact with tube) and calcium sulfate in the center (part that seawater passes through). Calcium sulfate is easier to be formed when the temperature goes higher.

When the amount of scales increases, the contact area of scale and cleaner is very small and a longer time of dissolution is required. Calcium sulfate cannot be dissolved by an acid cleaner.

RXSOL-54-1048-020 ( www.rxmarine.com/safe-acid-descalex-liquid-20-ltr ) is a powerful dissolving agent of calcium carbonate. Therefore, it is better to use RXSOL-54-1048-020  to do circulating cleaning at an early stage before the scales build up and block the tube, or regular cleaning is recommended as well. It is impossible to do a circulating cleaning when the tube is completely blocked.

FREE from ACID
Polymer based cleaner, which will result extra shinning and smooth feeling on surface.

Multiple action of RXSOL-16-0009-025 increases its popularity, And this product also can be use for DEGREASING and Carbon removal action.

 

Very popular and Effective cleaner for air coolers, scavenging air systems and turbo chargers of diesel engines, Coils of AHU, FCU, Air Conditioners (Indoor and Outdoor), Car Condenser and Radiator, Air Cooled Chillers, Air Cooled Condensers, Air Cooler Tube Bundle etc. 
 

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

For effective cleaning of air coolers, scavenging air systems and turbo chargers of diesel engines.
3 to 5 litres of cleaning solution per square meter or as table below:
      Engine HP.                Solution of RXSOL 009
     
6,000 to 12,000                   2 to 3 litre
      12,000 to 24,000                 4 to 5 litre
      24,000 or  more                   5 to 6 litre

In General : Depending upon contamination 10-25% with fresh water.

OPTIONAL : Dependant on design, the cooler is flooded with AIR COOLER CLEANER immersed in a tank full of product.
 

Hand spray Cleaning: By Hand spray,apply concentrate RXSOL-16-0009-210 all over the cooler coils. for good emulsification &penetration. Allow the RXSOL-16-0009-210 for a minimum of 10 MINUTES then use a high pressu ure  water to  wash  off  the  loosened deposits. During process  always  keep drain valve  open. After satisfactory cleaning, and flushing through with fresh water, close air cooler drains.Note that during this process the engine must be  stopped.

Immersion bath
Atleast for 2 Hrs deep COOLER PARTS in to  AIR COOLER CLEANER emulsion tank. The product should be heated to approx. 50°C and agitation provided with an air line. Then drain off and flush well with water, followed by drying with an air line.

Soak method: Machine parts with stubborn carbon deposits to be cleaned is dipped into conc.Soln.of ACC then allow deposits to. Be broken down and loosened before removal, then rinse .

Circulation method
Some designs of cooler can be circulated "in situ". In this case a pump tank and pipe system is fitted permanently or connections are provided for connecting a temporary circuit. The system should be filled with AIR COOLER CLEANER circulation carried out for 2 - 4 hours at a temperature of upto 50°C. After cleaning the cooler should be thoroughly flushed with fresh water and dried with an air line.

Note: Both cleaning methods benefit from heat of up to 50°C and cleaning times can be reduced or extended dependant on temperature and degree of fouling.

Note: 

1. It is a powerful solvent emulsion cleaner for cleaning of diesel engine air coolers, scavenging air systems and 
   compressor ...
2. ACC-009 is a liquid compound consisting of specific corrosion inhibitors , to prtect SOFT METAL

Field :: - AHU, FCU, Air Conditioners, Car Condenser and Radiator, Air Cooled Chillers, Air Cooled Condensers, Air Cooler Tube Bundle etc.

It has self foaming characteristics which starts immediate foaming when it comes in contact with dirt, enabling excellent penetration of the product into the coils for complete cleaning that instantly shows multiple increase of CFM/Air Velocity.

::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

Detailed Technical specification of individual components of chiller

A.    Refrigerant Compressors.

The refirgerant compressors shall be of hermitically sealed scroll type compressors with all standard accessories. The compressors shall be designed for continuous duty for a minimum period of 720  Hours. The approximate time taken by chiller unit for pulling down the intial load from ambient conditions of =40 degree C (maximum) to the designed process condition of - 45 degree C shall be clearly indicated. The refirgeration package shall also be provided with hot gas bypass arrangement ot act as an artificial heat load, during part load operations and also to recover the oil from the evaporator, as and when situation demands. System shall be designed to prevent starving of compressors during continous operations. The compressors shall be suitable for working on 415V, 3 phase, 50 Hz. AC  power supply and the terminal block shall have IP 64 protection. The compressors shall be of reputed make like Copeland, Germany/ Bitzer, Germany/ Dunfoss (Typical).

B.    Inter-stage Condenser.

The inter-stage condenser shall be of shell and tube type or al plate type of pack-less tube in tube type heat exchanger shall be designed and suitably selected with adequate heat transfer area. The heat exchanger shall be suitably thermally insulated with EPDM foam rubber of adequate thickness of class 'O' rating. While selecting the condenser capacity, all non-process side external heat loads like insulation losses, heat capacity of all piping material, pipe fittings, balance tank/ expansion tank etc. shall be adequately considered. These PHEs shall be of reputed make like WTT Germany/ Alfa Laval, Germany/ GEA (Typical)

C.    Water cooled condenser for high-stage refrigerant circuit 

Water cooled condenser to be used in the high side refrigeration circuit shall be of shell and tube type or a plate type or pack-less tube heat exchanger, designer suitably. The water available for cooling in the condenser is chilled water, and is available at a pressure of about 2-3 bar at a temperature of around 20-22 degree C. Adequate protection shall be considered for the chiller system for possible faults like insufficient cooling water flow, low cooling water pressire and high temperature of cooling water. Suitable cooling water pressure/ flow regulator, cooling water flow switch etc. shall be part of the system. The required cooling water flow rate and the temperature differential considered shall be indicated in the offer with all calculations, without fail. These water-cooled condensers shall be of reputed make like Danfos/ Copeland/ Bitzer/ Alfa laval(Typical). 

Short Description: 
ACC9 AC coil cleaner is powerful solvent emulsion cleaner, easily dissolves soiled oil and grease deposit. Also helpful to clean all types of engine parts, turbo chargers of diesel engines. During the operation, the fins & tubes of the main engine air cooler which become fouled with oil, grease, dus
Information: 

ACC9 is very effective to clean and dissolve oil, grease and carbon residues from machinery parts of air coolers, turbochargers and scavenging systems. We are keeping ready stock of materials at Mumbai, Surat, Gandhidham - Kandla Deendayal , Mundra, Manglore, Visakhapatnam, Chennai - Ennore, Kolkata - Haldia, Fujairah, Dubai - Sharjah. Proper cleaning of AIR COOLER  not only cooling efficiency can be improved but also Fire hazards can be minimised as build up of grease and oil residues are helpful to transmit fire from one point to others. Our continious work in chemicals field help us to add strong emulsifying agents in our Air cooler cleaner which acts as penetrating agent as well as cleaner to  remove grease and mud part created with mixture of mineral oils, grease, carbon soot  from air coolers and turbocharger.

In marine Industries Air cooler Cleaner also popular as ACC-9. Air Cooler cleaner ACC9 can be mixed with water in a cleaning tank then as per dependent of design, the cooler can be flooded with AIR COOLER CLEANER mixture by dipping in a tank. For enhancing cleaning action this water mixed product can be heated to approx. 50°C. Click here for ANIMATED TYPICAL cleaning Method. ( https://www.youtube.com/watch?v=qxvzFFd_IaA )

Carbon Remover also can be mixed with Air cooler cleaner to clean all types of diesel engine and heavy carbonized part remove oil, grease and carbon deposits from air coolers and scavenging systems. ACC9 is mixture of powerful solvent emulsion making surfactants, strong emulsifiers and penetrating agents formulated to penetrate and remove all oily deposited materials from diesel engine air coolers, scavenging air systems and compressor sides of turbochargers.

ACC-9 also named as Turbocharger cleaner, Compressor cleaner, Diesel engine cleaner.  Challenging product since 1995. Highest market share in India and Middle East giving us opportunity to make ACC9 in Bulk reactor of 4500 Ltr at a time in well defined glass reactor which is resulting Lowest price of ACC9 with pure and concentrated formulation. 

When ACC9  cleaner mixed with fresh water resulting mixture has no flash point, This is most important feature of ACC-9, which is resulting no fire risk operational area. And ACC9 is absolutely free from any kind of acid so resulting no fumes in work station. 

Formulated to remove oil, grease and carbon deposits from air coolers and scavenge systems. 

Air Cooler after hours of operation, the air cooler gets fouled and the result is lost engine performance. ACC9 - Air Cooler Cleaner can regain lost engine performance by flushing the air cooler with a hot chemical cleaning medium at low pressure.

Air cooler cleaner ACC9 available with us at almost all Indian and Middle East Location. Our huge stock location are Vizag - Visakhapatnam, Mumbai, Kandla - Gandhidham, Kolkata - Haldia, Surat - Hazira, Fujairah - Dubai - Middle East

Powerful AC coil cleaner

read more

Air Cooler Cleaner 210 Ltr

$
0
0

Alias: 

Mite ACC ,Nalfleet® 79101 ACC , Care Clean ACC , Air Cooler Cleaner Merichem..

Active Matter: 
94%
Application: 

During the operation, the fins & tubes of the main engine air cooler which become fouled with oil, grease, dust and carbonaceous deposit , which will affect cooler efficiency and damage the system.

Application

Immersion bath
Atleast for 2 Hrs deep COOLER PARTS in to  AIR COOLER CLEANER emulsion tank. The product should be heated to approx. 50°C and agitation provided with an air line. Then drain off and flush well with water, followed by drying with an air line.

Circulation method
Some designs of cooler can be circulated "in situ". In this case a pump tank and pipe system is fitted permanently or connections are provided for connecting a temporary circuit. The system should be filled with AIR COOLER CLEANER circulation carried out for 2 - 4 hours at a temperature of upto 50°C. After cleaning the cooler should be thoroughly flushed with fresh water and dried with an air line.

Note: Both cleaning methods benefit from heat of up to 50°C and cleaning times can be reduced or extended dependant on temperature and degree of fouling.
 

Packing Size: 
210.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

For effective cleaning of air coolers, scavenging air systems and turbo chargers of diesel engines.
3 to 5 litres of cleaning solution per square meter or as table below:
      Engine HP.                Solution of RXSOL 009
     
6,000 to 12,000                   2 to 3 litre
      12,000 to 24,000                 4 to 5 litre
      24,000 or  more                   5 to 6 litre

In General : Depending upon contamination 10-25% with fresh water.

OPTIONAL : Dependant on design, the cooler is flooded with AIR COOLER CLEANER immersed in a tank full of product.

 

Note: 

1. It is a powerful solvent emulsion cleaner for cleaning of diesel engine air coolers, scavenging air systems and 
   compressor ...
2. ACC-009 is a liquid compound consisting of specific corrosion inhibitors , to prtect SOFT METAL

Field :: - AHU, FCU, Air Conditioners, Car Condenser and Radiator, Air Cooled Chillers, Air Cooled Condensers, Air Cooler Tube Bundle etc.

It has self foaming characteristics which starts immediate foaming when it comes in contact with dirt, enabling excellent penetration of the product into the coils for complete cleaning that instantly shows multiple increase of CFM/Air Velocity.

 

Short Description: 
It has self foaming characteristics which starts immediate foaming when it comes in contact with dirt, enabling excellent penetration of the product into the coils for complete cleaning that instantly shows multiple increase of CFM/Air Velocity.

Antiscalant RO

$
0
0

This is a reverse osmosis membrane treatment chemicals. It is highly concentrated polymer chemicals. Antiscalant manufacturer, supplier and Exporter.
 

Alias: 

HYPERSPERSE MDC220, Antiscalant RO, Disperso 370, Flocon 135, Membrane Support PURE 9900, VITEC 5300, HYDREX 4102

Active Matter: 
90-92
Application: 

RO antiscalant

Scaling is caused in membranes because the level of hardness salts in the water becomes highly concentrated as it passes through the RO unit. In smaller units scale formation can be prevented by base exchange softening the make-up water but for larger systems that is very expensive. We have developed a range of easy to handle, cost-effective RO Antiscalant which increase the solubility of the hardness salts so they remain in solution rather than forming scale on the membrane. Our cost-effective RO antiscalants will inhibit a wide range of foulants including calcium carbonate, calcium sulphate, barium sulphate, strontium sulphate, calcium fluoride, silica and iron.

RO Antiscalants are dosed directly to the RO feed water tank or feedwater line (after pretreatment) at the recommended dosage of 1-3 mg/L and maximum dosage at 8mg/L, subject to inlet water quality and parameters is respect of Calcium Hardness, Iron, TDS, Alkalinity, pH and silica content. Maximum dilution should be 10% with RO or DI water for temperature less than 30 deg C. For higher temperature the dilution ratio can increase. 
 

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Dosing Guidelines: 

The typical dosage range is between 2 to 5 ppm or Typical dosage range is between 2 and 6 mg/L.

Dilution:

This product is formulated to be injected neat. However, if a dilution is required, use demineralized or RO permeate water. If neither of these is available, softened water may be substituted. The dilution for Vitec 1000 should not result in a solution strength of less than 10%. This guidelin will protect the effectiveness of the internal bacteriostat which inhibits bacterial growth in the drum and feed tank.Maximum dilution is temperature related as shown below.
Temperature, °C     Maximum Dilution, %
<30                                        12
30-35                                     25
>35                                        50

Packaging and Storage:

Standard regional pack sizes are listed below and custom packaging can be provided worldwide. This product should be protected from freezing.

Specifications
Appearance: Yellow liquid
pH (10% solution): 2.9

Specific Gravity@20oC

1.67 - 1.2

Packing 30 Kgs, 230 Kgs drum.

Note: 

Key Features and Benefits

  • Inhibit scale formation and effectively controls corrosion
  • Protects the membrane efficiently
  • Enhance the plant operation and equipments life span
  • Economical
  • Easy in usage and handling
Short Description: 
This is a reverse osmosis membrane treatment chemicals . It is highly concentrated polymer chemicals.

Key Features and Benefits

  • Effective scale inhibition 
  • Alkalinity builder 
  • High recovery rate 
  • Low Chemical dosage 
  • Cost Effective 
  • Effective Iron fouling control by sequestration 
  • Reduced frequency of membrane cleaning 
  • Compatible with all types of membranes 
  • Completely organic and biodegradable 

Our RO Antiscalant  is dosed directly to the RO feed water tank or feed water line (after pretreatment) at the minimum recommended dosage of 1ppm and maximum dosage at 15ppm, subject to inlet water quality and parameters is respect of Calcium Hardness, Iron, TDS, Alkalinity, pH and silica content. 

In case of high iron content of about 0.5 to 1.0ppm, the dosing has to be increased by 10-15ppm for stabilizing Calcium. 

At about 10-15ppm dosage our RO Antiscalant (HIGH PH) is capable of fully inhibiting iron and calcium, and silica up to 166ppm. For higher silica content RXSOL ANTISCALANT should be used. 

Antiscalant RO                                   RXSOL-33-3302-025
Antiscalant C.I ALKA                          RXSOL-33-2034-025
Membrane Antiscalant ALKA 191T    RXSOL-33-3321-030 
Antiscalant ORG EV 2030                 RXSOL-33-3325-230
Antiscalant RXSOL ORG EV             RXSOL-33-3327

 

Performance:

This product offers a variety of critical performance and application benefits: Inhibits RO membrane scaling caused by the following:

Calcium Carbonate:  CaCO3
Calcium Sulfate: CaSO4
Barium Sulfate: BaSO4
Strontium Sulfate: SrSO4
Calcium Fluoride: CaF2

Antiscalant  RO manufacturer and supplier Mumbai, Kandla, Chennai, Visakhapatnam, Kolkata, Surat, Fujairah, Dubai, Sharah, Abudhabi, Oman.

RO antiscalant

MICRO BIOCIDE Cooling Water 25 Ltr

$
0
0

Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors.

Alias: 

GREEN MICROBIOCIDE, MICROORGANISM CONTROL, Rocide BC 601, BIOCIDE INDION- 7705, CARETREAT 5 SEAWATER, Ferrocid 8583 MAXTREAT 606 CHEMICAL

Application: 

Microbiocide based on Organo sulphur compound, for use in open recircurculating systems.

* Highly effective
* Broad spectrum activity
* Economical and easy to use
* Compatible with other treatments.

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Routine dosage of Rcocide BC 601 to 50 to 100ppm. based on the total water capacity of the system. Dosage will be necessary once or twice per week depending on the severity of the problem.

For badly fouled systems, initial higher dosage of 100-150 ppm. should be given for the first week or two.

The calculate quantity of biocide should be added directly to the system at any convienient point.

Short Description: 
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors.

Sea Cleaner Plus 25 Ltrs

$
0
0

Alias: 

Sea Clean PLUS

Active Matter: 
93-95%
Application: 

Dosage Chart for Rock and Roll Cleaning

Fuel Oil Viscositry Centistokes at 50°C

RXSOL-20-2027-025 / 1000 Ltsof water

 

 

1st Stage

2nd Stage

Over 320 and sludge tanks

1 litre

1 litre

150 - 300

1 litre

0.75 litre

Up to 50

0.5 litre

Physical Properties

Colour

Light brown liquid

 

Density

In g/cm3 at 15°C: 0.9

 

Flash Point

Above 70 °C

 

PACKAGING

Order No

RXSOL-20-2027-025

Size (in litres)

20 , 25 , 35 , 210.

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Directions for Use and Dose Rates

RXSOL-20-2027-025 is  specially formulated for cleaning double bottom, deep and wing tanks etc, used for fuel oils. It can also be used for local cleaning and degreasing of engine rooms and on deck.

Soak Method

for heavy soil put parts into undiluted RXSOL-20-2027-025, for general soiling use a solution of 10-30% RXSOL-20-2027-025 in water. Parts should be soaked for at least 30 minutes before washing off with water.

Spraying Method

Use neat RXSOL-20-2027-025 over all soiled areas. Allow 10-20 minutes for reaction , then rinse with high pressure water hose., Scrubbing will assist the cleaning operation  for stubborn deposits.

Rock and Roll Method

Recommended time to clean and gas-free under normal circumstances would be 3-6 days ,for cleaning of double bottom tanks at sea.
1) First of all  heat the remaining oil in tanks .
2)By stripping constantly. flush the tank with sea water, 
3) Close  all suction and discharge valves .
4) 1st  Dose  Fill the tanks by ½ to 1 litre RXSOL-20-2027-025 per tone of     water   through pipe or manhole , for  75-80% of capacity of tank to be cleaned.
5) Then fill tank to 25% capacity with sea water, raise the temperature up to 60°C maximum, and maintain this temperature for 24 hours.
6) Top up tank to 75-80% capacity with sea water, continue to heat for 48 to 72 hours.
7) Discharge and strip tank. Fill to 50-60% capacity with sea water and allow 2 hours rinsing time.
8) Discharge tank and strip, flushing tank with sea water for 2 hours,stripping continuously. When completed, inspect tank to ascertain if second cleaning is required. If so:
9) For completion add second dose of RXSOL-20-2027-025, fill tank with sea water 75-80% capacity and raise the temperature to 60°C maximum. Maintain this for 48 to 72 hours. And recirculate the solution .
10) Discharge and strip tank, flush with sea water, stripping continuously for 2 hours.
11) To gas-free, fill tank with sea water to overflow through vents and sounding pipes, discharge and strip completely.

Note: 

RXSOL-20-2027-025 is an effective  liquid blend of  modern low toxic, biodegradable solvent, concentrated emulsifier with penetrating agents, mild abrasives and wetting agents which makes this an excellent  liquid scouring cleansers  for cleaning and degreasing action which makes useful for Cargo tank cleaning after drying, semi-drying. And non-drying natural oils and fats. Saponifying and detergents.

Similar familly group of this product is Tank clean Plus, Clean break, Seaclean, Tankleen. 

Short Description: 
Specially formulated for cleaning of double bottom, deep and wing tanks etc, used for fuel oils. Also for local cleaning and degreasing of deck and engine rooms, Oil installations, workshops, plant yards, industrial plants as degreaser and cleaner
Information: 

Seaclean is classified as marine base tank cleaning chemicals and degreaser. Its powerful degreasing action helps to clean and emulsify heavy oil and grease to make water soluble. SEACLEAN concentrated cleaner based on petroleum solvents, emulsifying agents and surfactants.

Seaclean, Sea Clean is powerfull solvent based degreaser. Seaclean easily penetrate oil greasy mud and also breakes the Carbonacious deposits.

Seaclean Plus most common degreaser in Shipping marine Industries. In shipchandling line Seacleaner is such a popular degreaser, no one need its eplanation about its uses. Sea clean can be utilized directly on metal surface or this can be diluted with water for light weight cleaning. Popularity of Seaclean plus is only due to its multi function properties. All Engineering section maintenance can be controlled by seaclean, And Seaclean plus also most common tank cleaner for lube oil / any petro solvent carrier.

Seaclean Plus supplier in Mumbai, Surat, Gandhidham - Kandla Deen Dayal Port, Sikka - Jamnagar, Manglore, Goa, Chennai - Ennore, Visakhapatnam - Gangavaram, Kolkata - Haldia, Paradip, Fujairah, Sharjah, Abu Dhabi, Dubai.

Sea clean specialized marine chemicals developed to clean fuel oil, petroleum-containing products, and also selected as one of best cleaning product for the double bottom, deep and wing tanks etc.

During our working field experience, we observed that Seaclean product also works as the powerful cleaner to dissolve stain of PET COKE, Presence of small quantities of seaclean can enhance cleaning action of pet-coke from ship bulk cargo hold. Simply spray seaclean on a heavily contaminated area of PET COKE and then use other ship hold cleaning chemicals like RX Tuff alkaline cleaner to complete hold cleaning process.

Seaclean degreasing and tankcleaning marine chemicals

read more

Sodium Hypo Chlorite (12-15%) 250 Kg

$
0
0

Alias: 

Chloros, Bleach, fungicide and an oxidizing bleach, Twin Oxide Compound A

Active Matter: 
<p> 12 - 15%</p>
Application: 
  • Also used as a disinfectant and germicide , especially in the sterilization of water.

  • It is also used for making wool unshrinkable and in the manufactire of chloroform.

  • For the purpose of disinfection and bleaching  , a weak soln. ( 1.2 % ) is used. For purifying water 0.02 to 0 .2 % volumetric is sufficientPotable Water Treatment

  • Aquatics and Pools

  • Odor Control/Corrosion Control

  • Food & Beverage Processing

  • Wastewater Treatment

  • Cooling Towers, Inland Power Stations & Industry

  • Irrigation Systems

  • Agriculture/Farming
     

HANDLING AND STORAGE PRECAUTIONS:

Do not store adjacent to chemicals that may react if spillage occurs. Comply with Oman regulations, when shipped. If closed containers become heated, vent to release decomposition products (mainly oxygen under normal decomposition). Do not mix or contaminate with ammonia, hydrocarbons, acids, alcohol or ethers.

DO NOT REUSE CONTAINERS: Product residues may remain in containers. All labeled precautions MUST be observed. Dispose of container in a manner meeting government regulations.

PRODUCT DISPOSAL:  Product should be completely removed from containers. Material that cannot be used or chemically reprocessed should be disposed of, in a manner meeting government regulations.

Packing Size: 
250.00 Kg.(Liq)
Image: 
Thumb: 
Using Procedure: 

A weak soln. ( 1.2 % ) is used. For purifying water
0.02 to 0 .2 % volumetric is sufficient for Potable Water Treatment

SODIUM HYPOCHLORITE

ACTIVE INGREDIENT:

            Sodium Hypochlorite as Chlorine                           : 15%

            Sodium Hydroxide                                                  :   1%

INERT INGREDIENTS:                                                      : 84%

             Total                                                                         100%           

 

General formulation to calculate  how much bleach is needed to add to a tank or a pipeline to disinfect it to a given chlorine residual using a given disinfectant. Usually someone wants to know how to meet an AWWA Standard (like C651-92, Disinfection of Water Mains). The equation below should be used to estimate the amount of sodium / Calcium hypochlorite (Chlorine Water is 6.00% sodium hypochlorite) needed to disinfect a given quantity of water to a desired chlorine concentration. 

                                                                        req'd residual in ppm
  Valume of hypo  =  volume of water  x  (  ----------------------------- )
                                                                           1,000,000 x hypo %

For example , say you had installed a new 5,000 gallon tank and wanted to make sure that you had at least a 100 ppm solution of chlorine in it.

How much 6.00% Hypochlorite would you need to add  ?

  • (5,000 gal x 100 ppm) / (1,000,000 x .06) = 8.33 gallons

How much 12% Hypochlorite solution would you need ?

  • (5,000 gal x 100 ppm) / (1,000,000 x .12) = 4.17 gallons

If you use calcium hypochlorite (the white, powder version of chlorine, like HTH pool cleaner), the equation becomes:

                                                                                                              req'd residual in PPM
Wgt. of Calcium Hypo (lbs)= gal of water x 8.33 lb / gal m x   ( ----------------------------- )
                                                                                                               1,000,000 x hypo %

  • This is simply the previous equation multiplied by the conversion factor of 8.33 pounds per gallon of water.

Let's assume that we still need to disinfect 5,000 gallons at 100 ppm.

How many pounds of 65% calcium hypochlorite (HTH pool cleaner) are needed?

  • (8.33 lbs/ gal. x 5,000 gal x 100 ppm) / (1,000,000 x .65) = 6.4 pounds
Note: 

High-test hypochlorite (HTH) is sold for chlorination of swimming pools and contains approximately 30% calcium hypochlorite. The crystalline salt is also sold for the same use; this salt usually contains less than 50% of calcium hypochlorite. However, the level of active chlorine may be much higher.

Note : Store in cool place

UN No :  1791
IMDG CLASS : 8

PACKING GROUP : III

ODOUR  : IRRITATING , PUNGENT ODOUR

R31: Contact with acids liberates toxic gases

R34: Causes burns

S-PHRASES

S1/2: Keep locked up and out of the reach of children.

S28: After contact with skin, wash immediately with plenty of water

S45: In case of accident or if you feel unwell, seek  medical advice (show the label where possible)

S50: Do not mix with acids

S50: Do not mix with reducing agents

X2: Restricted to professional users.Warning! Avoid exposure - obtain special instructions before use.

EMERGENCY AND FIRST AID PROCEDURES

EYE:

OBJECT IS TO FLUSH MATERIAL OUR IMMEDIATELY AND THEN SEEK MEDICAL ATTENTION IMMEDIATELY flush eyes with a directed stream of water at least 15 minutes while forcibly holding eye lids apart to ensure complete irrigation of all eye and lid tissue. Washing eyes within one (1) minute is essential to achieve maximum effectiveness. SEEK MEDICAL ATTENTION IMMEDIATELY.

SKIN:

SEEK MEDICAL ATTENTION IMMEDIAELY. Flush thoroughly with cold water under shower while removing contaminated clothing and shoes. CONTINUE TO FLUSH UNTIL MEDICAL ATTENTION ARRIVES. Discard non-rubber shoes. Wash clothing before reuse.

INIIALATION:

Remove to fresh air. If breathing is difficult, have trained person administer oxygen. If respiration stops, give mouth-to-mouth resuscitation. GET MEDICAL ATTENTION IMMEDIATELY.

INGESTION:

           NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. If swallowed, DO NOT INDUCE VOMITING. Give large quantities of milk or gelatin solution. If these are not available give large quantities of water. If vomiting occurs spontaneously, keep airway clear and give more milk, gelatin solution or water, GET MEDICAL ATTENTION IMMEDIATELY. Avoid vomiting, lavages or acidic antidotes. NOTE TO PHYSICIAN: Sodium Hypochlorite is an alkaline corrosive. For exposure by ingestion do not use emesis, lavages or acidic antidotes. Dilute immediately by giving milk, melted ice cream, beaten egg white, starch paste or antacids such as milk magnesia. Aluminum hydroxide gel or magnesium trisilicate gel. Avoid sodium bicarbonate because of  carbon di-oxide release. Sodium thiosulphate solution may prove beneficial by reducing unreacted material

 

Other Related PRODUCTS LINKS :

Textile Hypo Bleach , SODIUM HYPO CHLORITE , Sod Hypo Chlorite conc activeCHLORINE , CHLORINE LIQUID , Calcium Hypo Chlorite Conc active Chlorine , Chlorine Tablet cyanurate , Chlorine Tablets Calcium Based , DYE REMOVER ORG DICHLOR , Dechlorination Soln De-Hypo

Short Description: 
High-test hypochlorite (HTH) is sold for chlorination of WATER
Information: 

Sodium hypochlorite used for cleaning and disinfection. RXSOL is major manufacturer and supplier of highly purified chlorine bleach. Balancing of sodium hypochlorite ph also plays an important role during cleaning and other uses of sodium hypochlorite. free alkali containt required more neutrailzer during cleaning operation. All safety norms and physical and chemicals properties and  sodium hypochlorite chemical formula are updated in our MSDS of sodium hypochlorite sheet.

 

read more

Hydrazine Hydrate

$
0
0

No oxygen is entering the boiler with the feed water when hydrazine is present in the water.
 

The objective is to maintain a hydrazine residual between 0.05-0.2 ppm depending on operating pressure and boiler designe. Actual consumption is determined under operating conditions.  A normal dosage is approximately 1 ltr. per day, depending of system layout.

Application: 

it is used as an ANTIOXIDANT, an oxygen scavenger, and a corrosion inhibitor in water boilers and heating systems. Hydrazine is mainly used as a foaming agent in preparing polymer foams. No oxygen is entering the boiler with the feed water when hydrazine is present in the water.

Packing Size: 
50.00 Ltr.
Image: 
Thumb: 
Note: 

Test Procedure ::: rxmarine.com/hydrazine-test-kit

Short Description: 
it is used as an ANTIOXIDANT, an oxygen scavenger, and a corrosion inhibitor in water boilers and heating systems. Hydrazine is mainly used as a foaming agent in preparing polymer foams. No oxygen is entering the boiler with the feed water when hydrazine is present in the water.

read more

Slip Coat RXSOL HOLD BLOCK 25 Ltr

$
0
0

POLYMER BASED non-reactive coating materials which makes thin film barrier on the surface after dry. Due to the formation of RXSOL THIN barrier film on the surface, the cleaning operation after unloading becomes quicker and easier with optimum results.

Alias: 

Slip Coat Hold Block Resist, RBM HOLD BLOCK, GREEN BARRIER, HOLD SURFACE PROTECTOR, PRELOAD 300, HOLD BARRIER XR, Paint Protector

Active Matter: 
72-81
Application: 

Rxsol hold  block is a  Heavy Duty protective Solution for hold of vessels,  which carrying corrosive and / or messy cargos  such as sulphur salt petcock coal and concentrates. It can be easily removed with it

Recommendation Dose for smooth surface : 
for Sulphur, Salt, etc        100 Ltrs/Hold for HANDYMAX & 150 Ltrs/Hold for PANAMAX
& for Petcoke, Coal, etc   200 Ltrs/Hold for HANDYMAX & 250 Ltrs/Hold for PANAMAX

 

This materials can be use directly with low pressure machine or manually by garden spray pump. in general practice on smooth & clean surface  each drums of 210 ltrs covers 2000 to 2500 sq meter while on rough and rusted surface require more quantities of materials.

 

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

for HANDYMAX  (5 Holds) : In general  500 Ltr to 1000 Ltr   RXSOL-22-2210-210 require to cover area up to 12 mtrs , i.e approx 1/2 drum to 1 drum of material is sufficient for each hold , while
for PANAMAX    (7 Holds) : In general 1000 Ltr to 2000 Ltrs RXSOL-22-2210-210 require to cover full area. , i.e approx 3/4 drum to 1.25 drums of material is sufficient for each hold.

Note: 

This Emulsion is safe to use , But as a precaution goggles & Protective gloves with mask require before use of this materials.

Precaution : 1 > Deposition of previous cargo /  Lime wash should be removed .
                       2 > Newly Painted surface should be fully cured.

Other Valuable Hold Cleaners :::

Cement Remover RX Hold ::: Highly concentrated and powerful penetrating agents materials which is effectively react with cement to loosen the bonding strength . Best results can obtain on dry surface of cement. RXSOL'S R & D has developed this molecular cement dissolver. Part No.- RXSOL-22-2202-025, Part No.- RXSOL-22-2202-020,  Part No.- RXSOL-22-2202-050

Part No.- RXSOL-22-2202-035, Part No.- RXSOL-22-2202-210

 

 

Slip Coat RXSOL HOLD BLOCK  ::: Polymer EMULSION BASED non reactive coating materials which makes thin film barrier on surface after dry. Due to formation of RXSOL THIN barrier film on surface, the cleaning operation after unloading becomes quicker and easier with optimum results. Part No.- RXSOL-22-2210-210, Part No.- RXSOL-22-2210-025, Part No.- RXSOL-22-2210-050

 

BARRIER HOLD COAT ::: Highly effective ecofriendly Product blending of natural ingredients which is provide thin temprory film on Hold Surface to protect corrosion. This is making barrier between corrosive cargo like Sulphur, Salt, Petcoak, Cement etc and Hold surface. Part No.- RXSOL-22-2211-210

 

COAL REMOVER rx hold  ::: A powerful penetrating mixed chemical products to remove heavy coal deposits. Additionally, it may also be used to remove mineral deposits and eliminate bad odors in tanks and other closed systems. Part No.- RXSOL-22-2215-210, Part No.- RXSOL-22-2201-025, Part No.- RXSOL-22-2201-050

 

 

Hold Wash Concentrate RX ::: RXSOL hold wash is a versatile all purpose marine cleaning solution it can be used as a powerful stand alone cleaner for Petroleum oily stains and residues, vegetable and animal fats, as well as dirt, proteins, soils, coal, ore, coke or in combination. Part No.- RXSOL-22-2204-210, Part No.- RXSOL-22-2204-025, Part No.- RXSOL-22-2204-050

 

 

Rock Phosphate Cleaner rx hold  ::: A powerful penetrating mixed chemical products to remove heavy Rock Phospate deposits. Additionally, it may also be used to remove mineral deposits and eliminate bad odors in tanks and other closed systems. Part No.- RXSOL-22-2201-210

 

PCS Hold Clean ::: RXSOL PCS is an innovative, concentrated liquid product specifically engineered to attack, penetrate and remove Coal Carbon, pet coke, lime deposition accumulations from cargo and storage tanks, Also Developed for cargo hold cleaning to remove stains.  Part No.- RXSOL-22-2208-210

 

HBI CARGO Hold Wash Concentrate RX::: RX HBI CARGO Hold Wash Concentrate RX is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO . it can be used as a powerful\ stand alone cleaner for HBI CARGO dust and deposition. Part No.- RXSOL-22-2216-210, Part No.- RXSOL-22-2216-025

 

 

Short Description: 
Polymer EMULSION BASED non reactive coating materials which makes thin film barrier on surface after dry. Due to formation of RXSOL THIN barrier film on surface, the cleaning operation after unloading becomes quicker and easier with optimum results.
Information: 

Polymer based water soluble liquid product which is resulting thin transparent and  temporary film on cargo hold surfaces. Polymer based Thin film acts as barrier layer between the cargo and the ship hold surfaces.

 

Slip Coat RXSOL HOLD BLOCK is a Heavy Duty protective Solution for the hold of vessels which carrying corrosive and / or messy cargos such as Sulphur, Salt, Petcoke, coal and concentrates. It can be easily removed after discharging of cargo .
FEATURES AND BENEFITS:...................................
$ Protects metal against corrosive cargo.
$Safe on all coatings, and to the personnel handling it.
$ Protects paint against cargo penetration.
$ Environmentally friendly.
$ Safe to use in occupied / covered areas.
$ Reduces turn around times.
$ Easy to Direct Spray.
 

Other Important materials, which help to control corrosion on the metal surface. Chemically SULPHUR producing STRONG acid in presence of  moisture under excess of temperature, Freshly prepared acid during the reaction rapidly damaging steel surface. This can be prevented by ACID neutralisation method. RXSOL BILGE COAT is specially meant to solve this issue. For more details of product, You may click here to know more details about product and using procedures.

RXSOL Bilge Coat (Sulphur Acid Neutralizer)  Acts as Acid Neutralizer formed during sulphur voyages

HOLD BLOCK chemicals supplier.

FAQ - Slip Coat

Capt. ravi.prakash 4:54 PM (3rd JAN'19)
to RX MARINE INTERNATIONAL 
Dear Sir,
Ref our telcon, please find attached Hold photos after discharging of Australian Coal and cleaning (without applying any chemicals) in oct 2018 . Then vsl loaded Indonesian Coal and will be discharging same in abt a week. Next voyage is getting fixed to load Urea from Saudi. Basis the photos, which chemical would you suggest to be used. We were thinking of RXSOL PCS along with Aquatuff. Fyi, Owners have supplied 1200 Ltrs of Aquatuff HF last month. 
Thanks & best regards,
Capt. ravi.prakash
::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::

Dear Sir,

In image we can observe that BOTTOM line of hold is rusted, And your plan to load CLEAN CARGO like urea which is ammonia-ted product can result further heavy rusting. So here our suggestion is to go with PCS with Aquatuff HF. And after cleaning hold rust can be treated with RUST CONVERTOR by the ratio of 1:100 Ltr with water, this will change free iron rust content to orginal metal colour. ( For treatment of rust Each Hold  maximum 50 Ltr RUST CONVERTOR REQUIRED ) and Finally HOLD can be treat with SLIP COAT polymer, with dilution ration of 1:100 Ltr with Water. ( For Each Hold polymer coating  maximum 50 Ltr Slip Coat REQUIRED )

Refer this link to get IMAGE of CARGO HOLD. http://rxmarine.com/sites/default/files/CARGO HOLD CONDITION REPORT 12.10.2018(1).xlsx 

USES of slip coat provide transparent POLYMER layer in between UREA and HOLD surface.

Application of SLIP COAT is always be wise decision, this will not only protect hold metal surface from UREA contact, but also helps to release cargo without adhesion on cargo.

 

Thanking you

WBRGDS

Silvi

http://rxmarine.com/sites/default/files/CARGO HOLD CONDITION REPORT 12.10.2018(1).xlsx

Slip Coat Hold block supplier in all major port of India and Middle East. We are keeping ready stock at Kandla, Mundra, Sikka, Navlakhi, Hazira, Mumbai, JNPT, Visakhapatnam, Gangavaram, Chennai, Ennore, Kolkata, Haldia, Paradip, Fujairah, Dubai, Sharjah, Abu Dhabi. Slip coat also works as surface releasing agent and due to its chemicals resitance nature protect metal surface of ship from hazardoue cargo.

Protective Chemicals suitable for both sulphur and petcoke cargoes

Bentonite Powder

$
0
0

Bentonite Supplier for Oil Field Industries. It is a drilling - grade Bentonite which is naturally occuring clay .It is a High Yield Natural Sodium montomorillonite. It meets API 13A Standards.

Bentonite, very fine grind material mostly composite by clay mineral, especially montmorrilonite which chemically describe as hydrous alumina-silicate which contain small amounts of alkali and alkali -earth metals.

Alias: 

Bentonite API, Montmorrilonite

Application: 

• It is Viscosifier and Filtration control agent for water based Mud Systems.
• It is used in drilling muds for controlling bore hole stability. It is utilized in drilling muds to extract drill cuttings from the bit.
• It is also used for clearing cat litter

Bentonite, sometimes refer as sometimes referred to as Montmorrilonite is a naturally occurring substance, composed of a number of layers, each approximately 10 angstroms thick, and each consisting of two tetrahedral and one octahedral unit. This structure is responsible for three important characteristics, the ability to absorb large amounts of moisture, the ability to exchange ions and thixotropic gel formation.
 

Bentonite Powder

We are reputed as one of the most overruling Bentonite Mineral Powder Manufacturers and Suppliers in India. The unmatched quality and efficacy of Bentonite Powder in various sectors like Drilling, Effluent Treatment, Electrical, Engineering, Fertilizer, Foundry, Iron ore Pelletization, Liquor & Food, Pesticides and Pharmaceutical has played a vital role in the enhancement of the demand. Moreover, Bentonite Clay Powder is available in varied grades.

 

Application

Drilling

Effluent Treatment

Electrical

Engineering

Fertilizer

Foundry

Iron ore Pelletization

Liquor & Food

Pesticides

Pharmaceutical

Packing Size: 
50.00 Kg.(PWD)
Image: 
Thumb: 
Using Procedure: 

Bentonite can be Broadely classified in 2 grades :
 

Granular: Granular is the preferred option for filling trenches where the conductor is covered with Bentonite and then water poured over and mixed in the trench.

 

Powder: Powder is the preferred method for pouring into bore holes to en-sure the mixture is of a thin enough consistency to reach the bottom of the bore hole. If diamond drilling is required for deep holes, possible 40m depths and deeper and the Bentonite is to be pumped through the core in to the hole, then powder would be the preferred option.

 

The greatest application of bentonite in industries is the result of its swelling property, while combine with water able to perform multitude jobs. The sodium bentonite having more water absorption capacity makes it suitable for industries like Foundry and Civil engineering application and the calcium bentonite absorb lesser than Sodium still it has some special application like cosmetics, paper, Animal feed binder as many more to describe. Swell Well Mine Chem drilling grade Bentonite is basically a sodium bentonite acquired naturally from the mines. The mineral is processed using the advanced chemical technology for drilling from ores. The below features highlights the quality of the Swell Well Mine Chem Drilling Bentonite, Offers impermeability, Provides high barrel yield. Bentonite is valued in foundry sand binding, drilling mud and sealing agent in civil engineering works, bentonite is used as a mud constituent for oil and water well drilling. Swell Chem Mine is offering Bentonite products for drilling industry. What is Drining Bentonite ? Drilling Bentonite is the Bentonite formed to be used in drilling mud or fluid.

Note: 

Advantage

• It helps improve hole cleaning capacities of drilling fluids.
• It is effective as a filtering agent.
• It promotes borehole stability.
• It can be added directly to fresh water or fresh water based drilling fluids.

Short Description: 
Maximum swelling property, while combine with water, Our fine quality of sodium bentonite having more water absorption capacity then ordinary one.
Information: 

 Bentonite premium quality products exporter from India to Middle East - Dubai.

Various grade of Bentonite :::

Drilling Grade 1

API 13A Section – 9 Grade Bentonite Powder:

Physical Analysis:

PROPERTIES

PROTOCOL

UNIT

REQUIRED

RESULT

Viscometer Dial Reading at 600 rpm

API Spec. 13A:2004/ ISO 13500: 1998

r/min

30

36

Yield Point / Plastic Viscosity Ratio

API Spec. 13A:2004/ ISO 13500: 1998

_

3 Max

2.5

Filterate Volume

API Spec. 13A:2004/ ISO 13500: 1998

ML

15 Max

14.6

Moisture Content

API Spec. 13A:2004/ ISO 13500: 1998

% by weight

10.0 max.

10

Dry Screen Analysis(Residue Greater than 75 Microns)%

API Spec. 13A:2004/ ISO 13500: 1998

% by weight

4.0 max.

3.0 - 4.0

 Drilling Grade API Packing 25 Kgs 

 

IOP Grade Bentonite lumps :

Properties

Protocol

Unit

REQUIRED

Moisture Content

API Spec. 13A:2004/ ISO 13500: 1998

% by wt.

12% to 40 % max. 

LOI

IS:2000(P-1)-1985

% by wt.

5 – 10.

Free Swelling Volume 2gm/100ml

ASTM D 5890:1995

ml 

32 min.

PH Value of 5% gel 

IS:6186-1986

pH

8.0 – 10.0

Plate Water Absorption  (16 hours)

ASTM E 946

%

720- 760

Gel Time 2.5gm/25 ml

IS:12446-1988

second

Instant

Methylene Blue Value

API spe 131:2004/ ISO 10416:2002

mg/gm of clay

350 - 400 

Lumps size

IS:6186-1986

%

10 to 40 m.m.

Chemical specification:                                           

Alumina as AL2O3%>15.0-19.0                                 Sodium max 2.70

Calcium as  Cao%1.5-2.0                                           Na2O      2.0-2.5

Mgo  2.5-3.5                                                            iron as Fe2o3% 13.0-18.0

 

IOP Grade Lumps | 25 Kg Packing 

Product: Benotonite Powder for Grouting

Physical Analysis:

Properties

Protocol

Unit

Result

Liquid Limit

IS:12446-2007

ml/100 gm

350 - 450

Moisture Content

API Spec. 13A:2004/ ISO 13500: 1998

% by wt.

12.0 Max

Dry Screen Analysis (passing through 75 um sieve)

IS:12446-2007

% by. Wt.

85.0 min.

Free Swelling Volume 2gm/100ml

ASTM D 5890:1995 or IS:12446-2007

ml 

30 min

PH Value of 5% gel 

IS:12446-2007

pH

9.5  - 10.0

Gel Time 2.5gm/25 ml

IS:12446-1988

second

Instant

Filterate Volume

API Spec. 13A:2004/ ISO 13500: 1998

ml

20 max

Viscosty at 600 rpm

API Spec. 13A:2004/ ISO 13500: 1998

 

30 min

Methylene Blue Value

API spe 131:2004/ ISO 10416:2002 / IS:12446-2007

mg/gm of clay

350 - 400

 

Grouting Grade | 25 Kg Packing

 

PRODUCT: Ceramic Grade Bentonite Powder

Physical Analysis:

Properties

Protocol

Unit

Result

Free Swelling Volume 2 gm/100ml

IS:12446-2007

ml

12 - 18

Base Exchange Capacity

IS:12446-2007

 

70 - 80

Moisture Content % by weight

IS:12446-2007

%

10.0 - 12.0

PH Value  2% slurry

IS:12446-2007

0pH

8 - 9

Quartz Content

IS:12446-2007

%

2 - 3 %

Dry Mesh % Passing 200 B.S.S

IS:12446-2007

%

85 Minimum

 

Ceramic Grade  | 25 Kg Packing

<

Sodium montomorillonite

ANTISCALANT 9209 RX ( seawater distillation plants )

$
0
0

Antiscalant 9209 RX is specially designed to control the development of scale in seawater distillation plants. It is based on a synergistic blend of phosphonates which are found to be more effective than other polymers at controlling carbonate and sulphate scale formation in sea water distillation units .

Alias: 

Hydrex 9209 , Metito M 915, Genesys LF

Application: 

PREVENTS IRON FOULING and SILICA ANTISCALANT properties.

  1. Convenient liquid formulation for automatic dosing using suitable dosing equipment.
  2. Prevents formation of hard scale in seawater distillation units.
  3. Performance surpasses other similar products.
  4. Cost effective concentrate.
  5. Effective at high temperatures.
Packing Size: 
30.00 Kg.(Liq)
Image: 
Thumb: 
Using Procedure: 

The correct dosage rate is dependant upon several parameters, including feed temperature, pH, and chemical analysis and will be specified by your VWS consultant after a detailed survey of your plant. To obtain the best results, Antiscalant 9209 RX should be added continuously using a suitable metering pump.
In general PRACTICE :
Antiscalant 9209 RX should be dosed continuously to the feed water upstream of the cartridge filters. Typical dosage rates are 2 – 4 mg/L.
Antiscalant 9209 RX may also be used in sea water applications where iron is present, recycle of brine is in use or there is no feed water pH reduction by acid dosing.

Typical dose rates are 0.5 – 1.0 mg/L
Antiscalant 9209 RX dose rate in the feed water should be less than 5 mg/L in potable water systems. 
Antiscalant 9209 RX can be diluted and is fully miscible with water in all proportions.

Note: 

Antiscalant 9209 RX  is an aqueous solution of neutralised phosphonic acid. It has been approved for use in potable water applications and does not contribute to assimilable organic carbon (AOC), which can act as source of nutrient for micro-organisms. 

Short Description: 
Antiscalant for Water Distillation Units , specially designed to control the development of scale in seawater distillation plants.

ANTISCALANT 9209 RX seawater distillation plants, Compatible with all types of polyamide membrane
ANTISCALANT 9209 RX powerfully Inhibits common scales Calcium carbonate/sulphate - Calcium phosphate,Barium/Strontium sulphate - Silica, Iron/Manganese

TRUCK Mounted Cleaner Descaler

$
0
0

Cleaning of Scale and mineral deposits from truckmount becomes very easy by using RXSOL-41-4148-010 ( TRUCK Mounted Cleaner Descaler ). Routine cleaning and removal of hard water deposits from truckmount heat exchangers, fittings, valves, screens, metering systems, sensors, and water lines etc always be wise deceision. RXSOL-41-4148-010 premium powder formula of specialty ingredients is a  for easier and safer cleaning. 

Alias: 

Truck Mount Descaler

Application: 

Good Advice Apply RXSOL-41-4148-010 on WET surface only, Do not let dry the product on surfaces without rinsing.  Every machine is different. Basically, pour liquified descaler ( powder with water premixed ) into the water box. If your truckmount has a bypass orifice remove it and replace the plug or cap on the manifold.

Packing Size: 
1.00 Kg.(PWD)
Image: 
Thumb: 
Using Procedure: 

Inhibitor protects truck mount components.

First of all mix 1 Kg powder with 4 Ltr water to get powder dissolve completely in to the BUCKET. Then disconnect truck mount water inlet and solution outlet hoses. Drain water completely from water box, Then add 4 Ltr powder mixed water into water box to dissolve. Then start engine to run solution through truck mount  atleast for 15 minutes to dissolve scale from surface. Finally connect water inlet hose and solution hose, flush with water for 5 minutes. Add 250ml of Alkali Cleaner RXSOL ORG - 6 to water box and run for 2 to 5 minutes to neutralise residual of scale ion. Then circulate system with clear water to remove all loose particle as well as cleaner present inside the system. 

 

Note For heavy scale build-up Truck Mount Descaler may be diluted with mix 1.5 Kg powder with 4 Ltr water and the solution should be circulated for a longer period.

Note: 

Dilutions rates recommended : 

Light Duty Cleaning      : 500 Gram  : 4 Ltrs WATER
Normal Cleaning           :  1 Kg  : 4 Ltrs WATER  15 minutes  or  Time duration can be increased up to 45 minutes for Heavy deposit cleaning.
Heavy Duty Cleaning    : 1 Kg  : 4 Ltrs WATER   15 minutes

Short Description: 
For removal of hard water deposits from truckmount heat exchangers, fittings, valves, screens, metering systems, sensors, and water lines etc
Information: 

Truck Mount descaler manufacturer, Supplier and exporter in various packing and customized packing. Truck mount descaler are avialable with us in Powder as well as in Liquid stage. Powder form of Descaler are easy to carry and storage while liquid stage of Truck mount descaler is easy to use and application. Liquid decaler cane be easily apply in to the system. Premix with water doesn't required as POWDER Truck mount descaler can't use directly for application, its mixing with water must  required.

With regular use of this quality product, Equipment perfomance can be increased. Its powdered formulation provides easier and safe handling. This product can be classified as a powdered inhibited descaler for removal of hard water deposits. Regular removal of scale deposit prevents blokage of hoses and protects delicate components of truck mount's.

Truck mount descaler
1 Kg can descale 1 TRUCKMOUNT  fully.  Pl. be note dont forget to order  250ml of Alkali Cleaner RXSOL ORG - 6 , As after descaling ORG-6 plays very important role to neutrailze entire system.

Inhibited descaler powder


Hydrogen Sulfide Scavenger

$
0
0

Hydrogen Sulfide Scavenger -RXSOL-50-5014-025

H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure

Alias: 

MC MX 2-1106 , H2S Scavenger

Active Matter: 
98-100
Application: 

Hydrogen sulfide (H2S) naturally occurs and may already by present informations can be the result of sulphate reduicing bacteria (SRB) in your process systems. Ones established, it can potantially be carried in hydrocarbon streams, resulting in servere gatharing lines, creating high failure rates in your production.

Through stratgic H2S scavenger applications and speaciality chemicals,Rx Marine International chemicals experts can help reduce H2S levels and lower overall solids in your system, reducing any gas or fluid souring while controlling corrosion.

If  you  encounter hydrogen sulfide in your system, Rx Marine International can perform a fluid compatibility test to determine H2S levels and customize a chemical solution to fit your production needs.

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Hydrogen Sulfide Scavenger is works as a corrosive Acidic GAS Remover from system as well as from working station. which is not only damaging precious instrument but also creating Worker Health  problem by attacking on respiratory system.

The neutralizing effect of H2S is the result of a simple chemical reaction between the components of an RXSOL-11-5014-210 molecule and an offensive, toxic odour molecule. 

       Hydrogen Sulfide (H2S) + RXSOL-11-5014-025  =  Bi Sulfide salt
       
The resultant products in the above equations are safe and stabilized compounds, which are neutral, harmless, and odour free. They dissolve in water and will not be re-released into the atmosphere in normal conditions.

Note: 

Benefits:

  • Improved safety due to reduced H2S content
  • Meet contract sales limit for H2S content
  • Removal of hydrogen sulfide gas from process systems, therefore reducing corrosion
  • The reaction products can be easily removed from the process systems
  • Maintains asset integrity and reduces the need for new equipment
Short Description: 
Removal of hydrogen sulfide gas from process systems, therefore reducing corrosion

read more

Scale Inhibitor with Antifoamer

$
0
0

Alias: 

ACTIVE SCALE CONTROLLER AND ANTI-FOAMING AGENT, KURIFLOAT M-305

Application: 

Technical Capabilities:
Available scale inhibiting chemicals are effective at preventing mineral deposits caused by compounds such as calcium carbonate, strontium sulfate, calcium sulfate, barium sulfate, iron sulfide and iron oxide. Selection of the appropriate scale inhibitor and dose will include water testing to identify the types and concentrations of scale forming compounds present in the water. For example, phosphonate-based scale inhibitors are effective at preventing carbonate and sulfate scales whereas, polymer-base scale inhibitors are effective for sulfate/carbonate scales of barium, strontium and calcium.

Technical Limitations:
The amount of scale that will precipitate out of water is dependent of temperature, pressure, water incompatibility and mineral content. Because these variables often fluctuate, predicting and controlling the type and amount of scale inhibitor to use can be difficult requiring constant operations adjustments to account for these fluctuating parameters.Recent concerns about potential toxicity issues associated with scale inhibitors have led the shale gas industry to evaluate alternative scale inhibitors such as polyaspartic acid. Polyaspartic acid is a manufactured amino polycarboxylic acid that can function as a scale inhibitor, corrosion inhibitor, dispersant, chelation agent, and water absorber. According to the manufacturer, polyaspartic acid is non-toxic, biodegradable, and non-polluting.

Costs:
Because the amount and type of scale that can precipitate out of water is dependent on many factors, a cost associated with application is variable. However, the volume of application is low relative to the overall composition of water for fracture treatment. For example, approximately 0.08% or 0.043% of fracture water in the Marcellus Basin and Fayetteville respectively, is composed of scale inhibiting chemicals.

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Short Description: 
Treatment is used to reduce the concentration of scale forming compounds that can accumulate in production wells, water and disposal wells, flowlines and surface equipment.

read more

RXSOL Altreat 400

$
0
0

Cost-effective recovery of fresh water from seawater is critical to a wide range of industries such as the power, chemical, marine, oil and gas industries. During the distillation process, the formation of scale on heat transfer surfaces can significantly reduce heat transfer efficiency and increase operation and maintenance costs. Scale formation depends on temperature, concentration and pH, but generally takes the form of:

Alias: 

Altreat 400

Application: 

RXSOL Altreat 400 scale inhibitor is a polycarboxylic acid that controls inorganic scale formation. Small amounts of this copolymer, based on maleic acid, effectively handles large quantities of dissolved salts, thus preventing precipitation,settling and baking onto heat transfer surfaces. RXSOL Altreat 400 also impairs crystal growth, modifying the crystal structure to create a soft sludge byproduct that does not adhere to heat transfer surfaces.RXSOL Altreat 400 readily dissolves in any type of water. The typical dosage to feedwater ranges from a minimum of two parts per million (ppm) to a maximum of 10 ppm, depending on the quality of the seawater. This versatile antiscalant effectively performs at the range of temperatures encountered during mechanical vapour compression and during single and multi-effect distillation processes.Test results demonstrate that RXSOL Altreat 400 is more effective than other scale inhibitors under variable conditions,including water type, temperature and run time.

Packing Size: 
210.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

Instructions for use

  • Normal dosing rate 2–10 ppm (max. 10 ppm), depending
  • on the properties of the water to be treated. Ensure adequate mixing at chemical tank before dosing into the system.
  • Recommended operating temperatures: 50°–80°C.
Short Description: 
During the distillation process, the formation of scale on heat transfer surfaces can significantly reduce heat transfer efficiency and increase operation and maintenance costs. RXSOL Altreat 400 also impairs crystal growth, modifying the crystal structure to create a soft sludge byproduct that does

read more

Heat Exchanger cleaner

$
0
0

DISSOLVES SLUDGE THAT BUILDS UP IN HEAT EXCHANGERS: HEAT EXCHANGER CLEANER is a liquid POLYMER - Acidic based new generation material that readily dissolves sludge that builds up in heat exchangers.
 

Alias: 

Chemtreat AH 7 for cleaning heat exchanger, indion-1507, phe descalant Plate Heat Exchanger Descaling Chemical

Application: 

PRODUCT ADVANTAGES:
• Compatible with zinc phosphate materials
• Not harmful to equipment
• Less hazardous than hydrochloric acid based materials
 

Packing Size: 
25.00 Ltr.
Image: 
Thumb: 
Using Procedure: 

HEAT EXCHANGER CLEANER:

PRETREATMENT TECHNICAL DATA SHEET:

USE & CONTROL INSTRUCTIONS:
Operating Properties (Typical):

Application: Maintenance product – special application Circulating the product through the heat exchanger.
OperatingConcentration: Free Acid: 0.9 - 1.7 points
Operating temperature: Ambient
Operating time: Typically at least 30 minutes.

Specific process conditions may warrant operating the above parameters outside of the typical ranges. Please consult your RX MARINE representative:

Charge Instructions:
HEAT EXCHANGER CLEANER is used as delivered at ambient temperatures. If time is not a factor in the clean out, the solution can be diluted up to 50% with water.

Charge details:
1) If used at the 50% dilution: Fill the clean tank approximately ½ full with fresh water.
2) Set valves to proper setting for clean out
3) Plumb the circulating system to the correct side of the heat exchanger Turn on.
4) Slowly add 1 gallon of HEAT EXCHANGER CLEANER for every two gallons of  bath (or use the HEAT EXCHANGER CLEANER neat)
5) Allow to circulate for at least ½ hour dependent on sludge.
6) Turn off pump and disconnect plumbing from heat exchanger
7) Flush heat changer with fresh water to remove residual acid.
8) Turn heat exchanger valves back to running positions.
It is important to circulate the solution through the heat exchanger for at least 30 minutes. The cleaning time will vary depending on the amount and type of sludge build-up. After the heat exchanger is cleaned, it is highly recommended that the  unit  be  flushed with water. If this step is not taken, an increase in the free acid of the operating phosphate solution might occur.

PRETREATMENT TECHNICAL DATA SHEET:

Analysis Procedures:
CAUTION: DO NOT PIPETTE BY MOUTH ::: Free Acid
Equipment needed:::
• Burette Assembly
• 5-ml pipette and bulb
• 250-ml flask or beaker
• 100 ml graduated cylinder

Reagents needed:::
• Bromophenol Blue indicator
• 1.0N Sodium Hydroxide

Free Acid Procedure:
1. Using a pipette, pipette 5-ml of your solution into a 100-ml graduated cylinder. Fill the cylinder to the 100 ml mark with DI or RO water, then mix by up ending 2-3 times.

2. Pipette 5 ml of the above dilution to a beaker or flask; add 4-5 drops of Bromophenol Blue indicator. Then add 1.0N Sodium Hydroxide drop-wise until the
solution changes from yellow to blue. Record the number of mls as points of Free Acid.

The concentration is calculated by multiplying the points of Free Acid times the HEAT EXCHANGER CLEANER factor 0.59. This equals the concentration in percent by volume
of HEAT EXCHANGER CLEANER in solution. Points of Free Acid X 59 = Percent by volume of HEAT EXCHANGER CLEANER

PRTREATMENT TECHNICAL DATA SHEET:

Points of Free
Acid
Concentration of HEAT
EXCHANGER CLEANER
in percent by volume
Addition of HEAT EXCHANGER
CLEANER per 100 gallons of tank
volume (based on using HEAT
EXCHANGER CLEANER at 50%)
1.7 125% 0
1.3 100% 0
0.85 50% 0
0.4 25% 25 gallons
0.2 12.5% 37.05 gallons
 
Note: 

Equipment:
The HEAT EXCHANGER CLEANER is used for cleaning Stainless steel heat exchangers.The external pump and circulating system employing the HEAT EXCHANGER CLEANER should likewise be made of stainless steel or of a suitable, non-corrosive plastic.

Short Description: 
DISSOLVES SLUDGE THAT BUILDS UP IN HEAT EXCHANGERS. This is a liquid polymeric acid based material that readily dissolves sludge that builds up in heat exchangers.

HEDP 60%

$
0
0

Alias: 

1-Hydroxy Ethylidene-1,1-Diphosphonic Acid [HEDP 60%], Hydroxyethylidenedi(phosphonic acid), Dequest 2010, Etidronic acid, HEDP, AQUACID 105EX, Chelating agent

Active Matter: 
58-62
Application: 

RXSOL-81-8160-250 chemically having wide range of applications including scale prevention and corrosion inhibition in water treatment. 

Hydroxy Ethylidene -1,1-Diphosphonic acid is organophosphonate with multifunctional properties like sequestration, deflocculation, threshold inhibition and hydrolytic stability, as a single active ingredient. Because of the combination of these properties Hydroxy Ethylidene -1,1-Diphosphonic acid has a wide range of applications. One of the most important applications is in scale prevention and corrosion inhibition in water treatment. 

Packing Size: 
275.00 Kg.(Liq)
Image: 
Thumb: 
Using Procedure: 

HEDP is used as chelating agent. The dosage of 1-10mg/L is preferred as scale inhibitor, 10-50mg/L as corrosion inhibitor, and 1000-2000mg/L as detergent. Usually, HEDP is used together with polycarboxylic acid. It is used as a strong chelating agent for metal ions like Ca, Mg & Fe in water treatment, textile applications. Its efficient inhibition for CaCO3 & CaSO4 alone or in combination with low molecular weight polymers. Very effective in protecting metal corrosion. HEDP also having very strong chlorine stability. 

Note: 

Storage for ten months in room shady and dry place. Safety Protection: Acidity, Avoid contact with eye and skin, once contacted, flush with water. 

Short Description: 
Chelating agent, Scale and Corrosion Inhibitor. Scale prevention and corrosion inhibition in water treatment.

HEDP is used as scale and corrosion inhibition in circulating cool water system, oil field and low-pressure boilers in fields such as electric power, chemical industry, metallurgy, fertilizer, etc.. In light woven industry, HEDP is used as detergent for metal and nonmetal. In dyeing industry, HEDP is

used as peroxide stabilizer and dye-fixing agent; In non-cyanide electroplating.

Etidronic acid / HEDP supplier and Exporter in Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Fujairah, Dubai, Sharjah, Abu Dhabi, Ajman.

Synthesis / Manufacturing Process of HEDP:
The primary raw materials used to manufacture HEDP are acetic anhydride and either phosphorus acid or phosphorus Trichloride. The phosphorus trichloride is converted to phosphorus acid within the reaction vessel, and then reacts with the acetic anhydride.

Uses / Application of HEDP
HEDP is used as a strong Chelating Agent for Metal Ions like Ca, Mg & Fe in water Treatment, Textile, Sugar Processing, Dye, Soaps & Detergents.

Etidronic acid

read more

Viewing all 962 articles